    <item>
      <title>Traceable calibration with 177Lu and comparison of activity meters at hospitals in Norway and Sweden</title>
      <link>https://www.theragnostics.no/en/publications/hindorf-2023-traceable/</link>
      <pubDate>Fri, 01 Dec 2023 00:00:00 +0000</pubDate>
      <guid>https://www.theragnostics.no/en/publications/hindorf-2023-traceable/</guid>
      <description>&lt;hr&gt;
&lt;p&gt;The activity meter is used to determine the activity of delivered radiopharmaceuticals, administered activity to patients and reference activity when gamma-cameras are calibrated prior to imaged-based dosimetry. The aim is to describe a procedure for cross-calibration of activity meters at different clinical sites, and report on &lt;sup&gt;177&lt;/sup&gt;Lu activity results when using factory-set calibration factors compared to when calibration is performed with traceability to a primary standard. Thirty activity meters placed at seven hospitals in Norway and Sweden from four manufacturers: Capintec, Commecer, NuviaTech and Veenstra were included. A stock solution with &lt;sup&gt;177&lt;/sup&gt;Lu was prepared at the local sites and measured in each activity meter with factory settings. The solution was shipped to the reference site at Lund University for measurements in a secondary standard activity meter. Deviations between local and reference activity measurements were determined for three geometries: 25-mL vial, 10-mL syringe and 1-mL syringe. The median of the deviations was 6.4 % for the 25 mL vial, 5.9 % for the 10 mL syringe and 6.8 % for the 1 mL syringe. The median of the deviations for the 25 mL vial, was 1.5 % for activity meters from Capintec, 7.0 % for Comecer, 11.0 % for NuviaTech and 2.4 % for Veenstra. The majority of the deviations were positive and the maximum deviation was 14.5 %. The activity of &lt;sup&gt;177&lt;/sup&gt;Lu measured in an activity meter with factory-set dial settings may yield deviations up to 14.5%, compared to activities measured with traceability to a primary standard. This would imply an undertreatment of patients.&lt;/p&gt;
</description>
    </item>
    